GSA
When it's your responsibility to keep an older facility up and running or you are responding to a sudden emergency, Atlas Engineering can assess your facility, plan and prioritize maintenance, and design repairs and upgrades to keep your facility on-line, effective, and safe.
When your facility has to stay in operation and be safe, we can help. Give us a call.
Contract Details
Facilities Maintenance Consulting & Structural Assessment
GSA Contract: GS-21F-024AA NAICS Codes: 541330, 541340, 541350, 541611
Facilities Maintenance
Atlas Engineering performs building and equipment assessments, determines maintenance and repair priorities, and designs repairs and upgrades for older or damaged facilities. We handle the tough jobs - Our people have decades of experience dealing with difficult, non-standard, and high-hazard facilities problems, including disaster response and recovery.
Services
- Facilities Condition Assessments
- Planning/ Budgets for Maintenance and Repairs
- Vulnerability Studies - Wind, Earthquake, Flood
- Damage Assessment and Emergency Measures
- Structural Load Capacity
- Design of Structural Repairs
- Waterproofing/ Building Envelope
- Infra-Red Moisture Detection
- Roof Evaluations & Cost Planning
- New Roof & Re-roof Design

Representative Projects
Structural Assessments at 60 Sites: Assessed current conditions, load capacity, required maintenance/repairs, and repair costs for 60 campus structures. University of North Carolina
Crane, Hoist, & Fall Protection Anchors: Inspection, load capacity testing, and marking for overhead hoists, cranes, and anchors, per OSHA 1910.179. John Deere Co., Biogen Idec, RVEF
Safety Assessments - Manways, Access Platforms, Catwalks: Design, inspection, load capacity analysis, and repair design. Multiple powerplants, industrial sites, & laboratories
Historic Tower - Condition Assessment: Condition and structural assessment for WWI Memorial Bell Tower, with repair scope and cost estimates. North Carolina State University
Fire/Blast Damage: Assessed structural damage, provided safety oversight, and escorted Federal investigators for entries into blast-damaged structures. US Chemical Safety Board
Roof Evaluation and Re-Roof Design, National Guard Facilities: Assessment and re-roof design and inspections, Taylorsville Armory and Ft Bragg Training Center. NC National Guard
Building Envelope Repairs at NC Ports: Investigated roof & wall leaks, designed repair plans, specifications, cost estimates, and inspected repair work. North Carolina State Ports Authority
Roof Condition Surveys & Maintenance Planning: Visual surveys, IR scans, and detailed maintenance planning for 2,450,000 sf of industrial roof. IBM Campus at Research Triangle Park
Roof-Top Solar Installation & Roof Design: Combine roof design with new structural supports for solar water heating system. Fetzer Gymnasium, University of North Carolina
Structural Assessments
Age, accident, or natural disaster can make a facility hazardous to use, or even to walk into. Rescue teams, investigators, and repair crews need to go in, and you need answers - Is it safe? Can we make it safer? How much is damaged, and how do we safeguard the rest?
We are experts in assessing structural hazards - whether from the slow effects of corrosion, decay, or settlement - or the sudden catastrophes like fire, explosion, high winds, or earthquake. Atlas Engineering works side-by-side with first responders, investigators, designers and builders, to make damaged structures safer places to enter and work.
Services
- Structural condition surveys
- Load ratings - old or damaged structures
- Structural vulnerability assessments
- Corrosion/ decay/ settlement damage
- Search & rescue - structural specialists
- Investigation teams - structural safety
- Emergency shoring design
- Damage documentation

Representative Projects
Structural Assessments at Campus: Assessed current conditions, load capacity, required maintenance/repairs, and repair costs for 60 campus structures. University of North Carolina
Wind Load Vulnerability Study: Predicted extent and cost of probable damage to nine major laboratories, due to Code-level wind loads. FEMA-funded study, University of North Carolina
Life-Safety Assessments - Industrial Access Manways & Platforms: Design, inspection, load capacity analysis, and repair design. Multiple powerplants, industrial sites, & laboratories
Historic Structures - Evaluated structural condition, stability, and repair requirements for National Register Historic Places. Warren Co Fire Tower, Lake Mattamuskeet Lodge, NC
Industrial Damage - Evaluated structural conditions after severe damage events at industrial facilities - grain & coal silos, power plants, manufacturing, and pharmaceutical plants. Multiple sites
Federal Investigations: Assessed structural damage, provided safety oversight, and escorted Federal investigators into fire and blast-damaged structures. US Chemical Safety Board, ATF
Urban Search & Rescue: Structural Specialist for collapse rescue operations. Deployments including Katrina, Ivan, Haiti, and Irene. Federal DHS/FEMA, State NCDEM USAR Teams
Structural Collapse Training: Course Development/Instructor - Structural Collapse First Responder, Wide-area Search, Structural Monitoring. North Carolina DEM USAR Teams
Rapid Structural Assessment Training: Course Development/Instructor - Structures for military Civil Affairs operations in austere environments. NCSU/ US Army 95th Civil Affairs Brigade, Ft Bragg